faults and treatment methods of lithium forklift battery -Volt Fault

1, battery voltage high :
fully charged and standby , a single or few cells’ volt is obviously higher then others, the other cells volts are normal.
Causes of fault:
①acquisition error;
②BMS equilibrium function is poor or failure;
③low cell capacity and fast voltage rising during charging.
Treatment methods:
① the read value of the cell voltage is higher than other cells, measure the real cell voltage and compared it to read value . If the real value is lower than read volt value and same as other cells , the BMS shall be adjusted by the actual value; if the measured value conforms to the displayed value, the single cell will be discharged manually.
② Check if voltage tap is broken or disconnected;
③replace BMS .
2, battery voltage low:
fully charged and standby , a single or few cells'volt is obviously lower then others, the other cells volts are normal.
Causes of fault:
①acquisition error;;
② BMS equilibrium function is poor or failure;
③bigger self-discharge rate;
④low cell capacity and fast voltage drop during discharge.
Treatment methods:
①the read value of the cell voltage is lower than other cells, measure the real cell voltage and compared it to read value . If the real value is higher than read volt value and same as other cells , the BMS shall be adjusted by the actual value; if the measured value conforms to the displayed value, the single cell will be charged manually.
② Check if voltage tap is broken or disconnected;
③replace the BMS;
④ replace the fault cell or module.
3, Volt deviation large:
dynamic volt deviation/ static volt deviation. During charging, the single cell voltage jumps rapidly to the overcharge voltage; on the accelerator, the single cell voltage drops rapidly than other cells; when brake, single cell voltage rises rapidly than other cells.
Causes of fault:
①connecting bar fastening nut is loose;
②bar bus dirt;
③large cell self-discharge rate;
④ cell Inveracious Soldering (causing the low capacity of cell );
⑤leakage of some cell.
Treatment methods:
① tighten the nut;
②clear the bar surface;
③ Balance the cells ;
④replace the failed cells or modules.
4, voltage jump:
The battery voltage jump when the vehicle is running or charging.
Causes of fault:
① the voltage taps are loose;
② the BMS fault.
Treatment methods:
① tighten the volt taps;