Home > Education > Content

faults and treatment of lithium forklift battery- Volt fault

Jun 09, 2021

faults and treatment methods of lithium forklift battery -Volt Fault

capacity degeration



 

1, battery voltage high :

 fully charged and standby , a single or few cells’ volt is obviously higher then others, the other cells volts are normal.

 

Causes of fault:

 ①acquisition error;  

②BMS equilibrium function is poor or failure; 

③low cell capacity and fast voltage rising during charging.

 

Treatment methods:

① the read value of the cell voltage is higher than other cells, measure the real cell voltage and         compared it to read value . If the real value is lower than read volt value and same as other cells , the BMS shall be adjusted by the actual value; if the measured value conforms to the displayed value, the single cell will be discharged manually. 

② Check if voltage tap is broken  or disconnected;  

③replace BMS .

 

 2, battery voltage low:  

fully charged and standby , a single or few cells'volt is obviously lower  then others, the other cells volts are normal.

 

Causes of fault:  

①acquisition error;;

② BMS equilibrium function is poor or failure; 

③bigger self-discharge rate;

④low cell capacity and fast voltage drop during discharge.

 

Treatment methods: 

①the read value of the cell voltage is lower than other cells, measure the real cell voltage and compared it to read value . If the real value is higher than read volt value and same as other cells , the BMS shall be adjusted by the actual value; if the measured value conforms to the displayed value, the single cell will be charged manually.  

② Check if voltage tap is broken  or disconnected;

 ③replace the BMS;

④ replace the fault  cell or module.

 

3, Volt deviation large:

dynamic volt deviation/ static volt deviation. During charging, the single cell voltage jumps rapidly to the overcharge voltage; on the accelerator, the single cell voltage drops rapidly than other cells; when  brake, single cell voltage rises rapidly than other cells.

 

Causes of fault: 

①connecting bar fastening nut is loose; 

②bar bus dirt; 

③large cell self-discharge rate; 

④ cell  Inveracious Soldering  (causing the low capacity of cell ); 

⑤leakage of some cell.


Treatment methods: 

① tighten the nut; 

②clear the bar surface; 

③ Balance the cells ; 

④replace the failed cells or modules.

 

4, voltage jump: 

The battery voltage jump when the vehicle is running or charging.


Causes of fault: 

① the voltage taps are loose; 

 ② the BMS  fault.


Treatment methods:

①  tighten the volt taps; 

②  replace the BMS

Send Inquiry